Altera Temperature Sensor Functional Description

Temperature Sensing Operation for Arria 10 Devices

Figure 1: Altera Temperature Sensor IP Core Top-Level Diagram for Arria 10 Devices

The following lists the features for Altera Temperature Sensor IP core for Arria 10 devices:
• For Arria 10 devices, the Altera Temperature Sensor IP core supports the instantiation of temperature

sensor block in your design from the IP Catalog.

• The Arria 10 temperature sensor block runs at 1 MHz, where the clock signal is coming from the

internal oscillator. Within the block, 10-bit ADC circuitry is included for converting sensor’s reading

to digital output.

• The

corectl

signal is used as an enable signal. When asserting the

corectl

signal, the ADC starts the

conversion and 10-bit data is available at

tempout

after 1,024 clock cycles. The

eoc

signal goes high for

one clock cycle indicating end of conversion. You can latch the data on

tempout

at the falling edge of

eoc

.

• You can reset the temperature sensor anytime by asserting the

reset

signal.

Related Information

Transfer Function for Internal TSD

Provides more information on how to calculate the temperature from the tempout[9:0] value.