Hsdi – Altera PowerPlay Early Power Estimator User Manual
Page 29

Altera Corporation
3–13
October 2005
PowerPlay Early Power Estimator User Guide: Stratix, Stratix GX & Cyclone FPGAs
Using PowerPlay Early Power Estimator for Stratix, Stratix GX & Cyclone FPGAs
shows the Stratix device PowerPlay early power estimator
and the estimated power consumed by the RAM blocks for a design
targeting a Stratix device.
Figure 3–12. RAM Blocks Section in the Stratix PowerPlay Early Power Estimator
HSDI
The HSDI section is only found in the Stratix device PowerPlay early
power estimator. Stratix devices contain dedicated circuitry that supports
interfacing with high-speed differential I/O standards at speeds up to
840 megabits per second (Mbps). Stratix devices support the
HyperTransport technology, LVDS, LVPECL, and 3.3-V PCML
differential I/O standards. The HSDI section in the Stratix device
PowerPlay early power estimator is divided into two parts: Receiver and
Transmitter.
Each row in the HSDI section represents a separate receiver or
transmitter domain. For each transmitter domain used, you need to enter
the data rate (in Mbps), the number of channels in that transmitter
Clock Enable %
Enter the average percentage of RAM clock enabled. The toggle percentage ranges from
0 to 100%. Typically, the toggle percentage is 100%.
# <type of RAM>
Blocks
Enter the number of M512, M4K or M-RAM blocks that are configured with the same clock
frequency, data inputs and outputs, toggle percentage and mode. This value is limited by
the number of RAM blocks available in the largest device in the family. Verify that the
number of RAM blocks entered does not exceed the number of RAM blocks available in
your target device. The PowerPlay early power estimator does not verify this.
Table 3–5. RAM Blocks Section Information (Part 2 of 2)
Column Heading
Description