Altclkctrl megafunction ports, Input ports, Output ports – Altera Clock Control Block IP Core User Manual
Page 19: Altclkctrl megafunction ports –7, Input ports –7 output ports –7, Input ports output ports

Chapter 3: Functional Description
3–7
ALTCLKCTRL Megafunction Ports
February 2014
Altera Corporation
Clock Control Block (ALTCLKCTRL) Megafunction
User Guide
ALTCLKCTRL Megafunction Ports
Table 3–3
and
Table 3–4
lists the input and output ports for the ALTCLKCTRL
megafunction.
Input Ports
Output Ports
Table 3–3. ALTCLKCTRL Megafunction Input Ports
Port Name
Required
Description
Comments
clkselect[]
No
Input that dynamically selects
the clock source to drive the
clock network that is driven by
the clock buffer.
Input port[1 DOWNTO 0] wide.
If omitted, the default is GND.
If this signal is connected, only the global clock
network can be driven by this clock control block.
ena
No
Clock enable of the clock buffer
If omitted, the default value is V
CC
.
This option cannot be used for periphery clock
network path in Stratix
®
III and Stratix IV devices.
inclk[]
Yes
Clock input of the clock buffer
Input port [3 DOWNTO 0] wide.
You can specify up to four clock inputs, inclk[3:0].
Clock pins, clock outputs from the PLL, and core
signals can drive the inclk[] port.
Multiple clock inputs are only supported for the global
and auto-selected clock networks.
Binary Value
Signal Selection
00
inclk[0]
01
inclk[1]
10
inclk[2]
11
inclk[3]
Table 3–4. ALTCLKCTRL Megafunction Output Ports
Port Name
Required
Description
Comments
outclk
Yes
Output of the clock buffer.
—