Chapter 2: Parameter Settings

2–5

Command Line Interface Parameters

February 2014

Altera Corporation

Clock Control Block (ALTCLKCTRL) Megafunction

User Guide

Command Line Interface Parameters

Expert users can choose to instantiate and parameterize the megafunction through the
command-line interface using the clear box generator command. This method
requires you to have command-line scripting knowledge.

f

For more information about using the clear box generator, refer to the

Introduction to

Megafunctions User Guide

.

Table 2–2

lists the parameters for the ALTCLKCTRL megafunction.

Table 2–2. ALTCLKCTRL Megafunction Parameters

Parameter Name

Type

Required

Comments

clock_type

String

Yes

This parameter specifies the operation mode. The values are:

The clkselect and ena ports are unavailable if the
clock_type

parameter is set to EXTCLK.

ena_register_mode

String

No

Register mode for the ena port. Values are NONE,
FALLING_EDGE, and DOUBLE_REGISTER. Only available in
Arria II GX, Arria II GZ, Arria V, Arria V GZ, Arria 10, Cyclone V,
Stratix III, Stratix IV, and Stratix V devices.

lpm_hint

String

No

Allows you to specify Altera-specific parameters in VHDL
Design Files (.vhd). The default value is UNUSED.

lpm_type

String

No

Identifies the library of parameterized modules (LPM) entity
name in VHDL Design Files (.vhd).

intended_device_family

String

No

Used for modeling and behavioral simulation purposes. Create
the ALTCLKCTRL megafunction with the MegaWizard Plug-In
Manager to get the value for this parameter.

implement_in_les

String

No

Specifies if you want the clock control unit to be implemented
using logic elements (LEs). Values are “ON” or “OFF”. The
default setting is “OFF”.

number_of_clocks

Integer

Yes

Specifies the number of global-type clock inputs. Values are
numeric type (1 to 4). For other clock types, only one clock
input is accepted.

use_glitch_free_switch_over

_implementation

String

No

Specifies if you want to implement a glitch-free switchover
when you use multiple clock inputs. Values are “ON” and
OFF”. If omitted, the default setting is “OFF”.

width_select

Integer

Yes

Specifies the width of the clock select when you use multiple
clock inputs. The clock select inputs dynamically selects the
clock source that drives the clock network. The values are 1 or
2. If omitted, the default value is 1, which means 1-bit width.

Value

Signal Selection

AUTO

Auto-selected clock
(default value)

GCLK

Global clock

LCLK

Regional clock

EXTCLK

External clock

SIDE_CLK

Dual-regional clock