Power supply design, Power supply design -3 – Altera MAX 10 Power User Manual
Page 6

Power Supply Design
Designing a power tree for a MAX 10 single- or dual-supply device will vary depending on the static and
dynamic power, as well as I/O and other feature utilization, for each specific use case.
Altera
®
Enpirion portfolio of power management solutions, combined with comprehensive design tools,
enable optimized MAX 10 device power supply design. The Enpirion portfolio includes power
management solutions that are compatible with all MAX 10 variants.
The MAX 10 FPGA Device Family Pin Connection Guidelines provides a more detailed recommendation
about how to group inputs in order to power a MAX 10 device. The PowerPlay Early Power Estimators
(EPE) tool for MAX 10 devices provides input rail power requirements and specific device recommenda‐
tions based on each specific MAX 10 use case.
Individual input rail voltage and current requirements are summarized on the Report tab while input rail
groupings and specific power supply recommendations can be found on the Main and Enpirion tabs,
respectively.
Warning:
MAX 10 single-supply devices have maximum power consumption of V
CC_ONE
, as listed in the
following table. Running a design that goes beyond the maximum power consumption of
V
CC_ONE
of the MAX 10 single-supply device may cause functional issue on the device.
Therefore, ensure that your device does not exceed the maximum power consumption of
V
CC_ONE
when you analyze the power consumption of your design using the PowerPlay EPE
spreadsheet.
Table 2-2: Maximum Power Consumption of V
CC_ONE
for MAX 10 Single-Supply Devices
Device
Maximum Power Consumption (W)
10M02S
0.778
10M04S
1.362
10M08S
1.362
10M16S
2.270
10M25S
2.943
10M40S
5.267
10M50S
5.267
Related Information
•
Provides more information about Altera's Power Management IC and PowerSoC solutions designed
for powering FPGAs.
•
Provides a more detailed recommendation about how to group inputs in order to power a MAX 10
device.
UG-M10PWR
2015.02.09
Power Supply Design
2-3
MAX 10 Power Management Features and Architecture
Altera Corporation