8.1
Technical details
8
Technical details
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
8-2
Technische Daten_Satz No.
No. stands for order number.
Si-Kennzahlen_alle
Si-Kennzahlen_Zusatz_Relais_1kan_EN954_Cat2
Requirement on 1-channel relay outputs for Cat. 2 in accordance with
EN 954-1: An additional output switches to a safe condition in the event
of an error or, if that is impossible, signals a hazardous condition.
Si_Kennzahlen_Erläuterung
All the units used within a safety function must be considered when cal-
culating the safety characteristic data.
Technische Daten_Satz Normen
The standards current on 2009-01 apply.
Si-Kennzahlen_Zusatz_Relais_Lebensdauer_BA
Housing material
Housing
PPO UL 94 V0
Front
ABS UL 94 V0
Cross section of external conductors with screw terminals
Power supply, inputs, auxiliary output, semiconductor out-
puts, test pulse outputs, cascading outputs:
2 core, same cross section, flexible:
Relay outputs:
1 core flexible
0.5 - 2.5 mm², 22 - 12 AWG
2 core, same cross section, flexible:
with crimp connectors, without insulating sleeve
0.50 - 1.25 mm², 22 - 16 AWG
without crimp connectors or with TWIN crimp connectors
0.50 - 1.25 mm², 22 - 16 AWG
Torque setting with screw terminals
0.25 Nm
Spring-loaded terminals: Terminal points per connection
1
Stripping length
9 mm
Dimensions
Height
94.0 mm
Width
22.5 mm
Depth
121.0 mm
Weight
170 g
175 g coated version
Safety characteristic data
Unit
Operating mode
EN ISO 13849-
1: 2006
PL
EN 954-1
Category
EN IEC 62061
SIL CL
PFH [1/h]
EN ISO
13849-1:
2006
T
M
[year]
relay outputs
single-channel
PL c (Cat. 1)
Cat. 2
-
2.90E-08
20
relay outputs
dual-channel
PL e (Cat. 4)
Cat. 4
SIL CL 3
3.00E-10
20
Mechanical data