beautypg.com

Pin assignment, Preparing for operation – Pilz PSEN im1 User Manual

Page 7

background image

PSEN im1

Operating Manual PSEN im1
21381­EN­02

7

}

Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing ele­
ment (e.g. retaining bracket or an end angle).

Pin assignment

Preparing for operation

}

Connect the PSEN im1 to

the test pulse outputs of the PNOZmulti

the inputs of the pressure­sensitive protective devices

}

Connect the pressure­sensitive protective devices to the inputs of the PNOZmulti base
unit

}

The configured test pulse outputs should be used exclusively for test pulses on the
pressure­sensitive protective devices.

}

Be sure to note the information provided in "Technical details".

}

Permitted per dual­pole input: max. 5 pressure­sensitive protective devices in series

}

Max. area of pressure­sensitive protective device = 8 m2