beautypg.com

Operation, Status indicators, Faults – interference – Pilz PZE X4V 8/24VDC 4n/o User Manual

Page 9

background image

PZE X4V8

Operating Manual PZE X4V8
1003204­EN­05

9

Setting the delay time

Operation

Status indicators

CH.1 
Safety contacts of channel 1 are closed.

CH.2 
Safety contacts of channel 2 are closed.

Faults – Interference

By closing or interrupting the input circuit you can check whether the unit switches on or off
correctly.

For safety reasons, the unit cannot be started if the following faults are present:

}

Contact malfunction: As the contact block is connected to a base unit,
reactivation will not be possible if the contacts have welded after the input circuit has
opened.

}

Open circuit, short circuit or earth fault ( e.g. in the input circuit)