Electrical data – WaterFurnace Envision (XL) User Manual
Page 14
ENVISION 7-25 TONS INSTALLATION MANUAL
15
Electrical Data
Rated
Voltage
Blower
Blower
Total
Min
Max
Voltage
Min/Max
Motor
HP
Unit
Circ
Fuse/
MCC
RLA
LRA
FLA***
***
FLA
Amp
HACR
Horizontal
208-230/60/3
187/253
16.3
10.4
88.0
4.8
1.5
25.7
28.3
35.0
080
460/60/3
414/506
9.0
5.8
38.0
2.4
1.5
13.9
15.4
20.0
575/60/3
518/632
5.9
3.8
36.5
1.9
1.5
9.5
10.4
10.0
208-230/60/3
187/253
16.3
10.4
88.0
6.2
2.0
27.1
29.7
40.0
080**
460/60/3
414/506
9.0
5.8
38.0
3.1
2.0
14.6
16.1
20.0
575/60/3
518/632
5.9
3.8
36.5
2.5
2.0
10.1
11.0
10.0
208-230/60/3
187/253
21.2
13.6
83.1
6.2
2.0
33.3
36.7
50.0
095
460/60/3
414/506
9.5
6.1
41.0
3.1
2.0
15.3
16.8
20.0
575/60/3
518/632
7.8
5.0
34.0
2.5
2.0
12.5
13.7
15.0
208-230/60/3
187/253
21.2
13.6
83.1
9.2
3.0
36.3
39.7
50.0
095**
460/60/3
414/506
9.5
6.1
41.0
4.3
3.0
16.5
18.0
20.0
575/60/3
518/632
7.8
5.0
34.0
3.4
3.0
13.4
14.6
15.0
208-230/60/3
187/253
24.9
15.9
110.0
9.2
3.0
41.1
45.1
60.0
120
460/60/3
414/506
12.1
7.7
52.0
4.3
3.0
19.8
21.7
25.0
575/60/3
518/632
8.9
5.7
38.9
3.4
3.0
14.8
16.2
20.0
Vertical
208-230/60/3
187/253
16.3
10.4
88.0
3.6
1.0
24.5
27.1
35.0
080
460/60/3
414/506
9.0
5.8
38.0
1.8
1.0
13.3
14.8
20.0
575/60/3
518/632
5.9
3.8
36.5
1.5
1.0
9.0
9.9
10.0
208-230/60/3
187/253
16.3
10.4
88.0
4.8
1.5
25.7
28.3
35.0
080**
460/60/3
414/506
9.0
5.8
38.0
2.4
1.5
13.9
15.4
20.0
575/60/3
518/632
5.9
3.8
36.5
1.9
1.5
9.5
10.4
10.0
208-230/60/3
187/253
21.2
13.6
83.1
4.8
1.5
31.9
35.3
45.0
095
460/60/3
414/506
9.5
6.1
41.0
2.4
1.5
14.6
16.1
20.0
575/60/3
518/632
7.8
5.0
34.0
1.9
1.5
11.9
13.1
15.0
208-230/60/3
187/253
21.2
13.6
83.1
6.2
2.0
33.3
36.7
50.0
095**
460/60/3
414/506
9.5
6.1
41.0
3.1
2.0
15.3
16.8
20.0
575/60/3
518/632
7.8
5.0
34.0
2.5
2.0
12.5
13.7
15.0
208-230/60/3
187/253
24.9
15.9
110.0
6.2
2.0
38.1
42.1
50.0
120
460/60/3
414/506
12.1
7.7
52.0
3.1
2.0
18.6
20.5
25.0
575/60/3
518/632
8.9
5.7
38.9
2.5
2.0
13.9
15.3
20.0
208-230/60/3
187/253
24.9
15.9
110.0
9.2
3.0
41.1
45.1
60.0
120**
460/60/3
414/506
12.1
7.7
52.0
4.3
3.0
19.8
21.7
25.0
575/60/3
518/632
8.9
5.7
38.9
3.4
3.0
14.8
16.2
20.0
208-230/60/3
187/253
35.0
22.4
149.0
3.6
1.0
52.0
57.6
80.0
160
460/60/3
414/506
16.5
10.6
75.0
1.8
1.0
24.8
54.0
35.0
575/60/3
518/632
12.0
7.7
54.0
1.5
1.0
18.4
20.3
25.0
208-230/60/3
187/253
35.0
22.4
149.0
4.8
1.5
54.4
60.0
80.0
160**
460/60/3
414/506
16.5
10.6
75.0
2.4
1.5
26.0
28.7
35.0
575/60/3
518/632
12.0
7.7
54.0
1.9
1.5
19.2
21.1
25.0
208-230/60/3
187/253
36.2
23.2
164.0
4.8
1.5
56.0
61.8
80.0
180
460/60/3
414/506
17.5
11.2
75.0
2.4
1.5
27.2
30.0
40.0
575/60/3
518/632
12.3
7.9
54.0
1.9
1.5
19.6
21.6
25.0
208-230/60/3
187/253
36.2
23.2
164.0
6.2
2.0
58.8
64.6
80.0
180**
460/60/3
414/506
17.5
11.2
75.0
3.1
2.0
28.6
31.4
40.0
575/60/3
518/632
12.3
7.9
54.0
2.5
2.0
20.8
22.8
30.0
208-230/60/3
187/253
47.0
30.1
225.0
6.2
2.0
72.6
80.1
110.0
240
460/60/3
414/506
26.0
16.6
114.0
3.1
2.0
39.5
43.6
60.0
575/60/3
518/632
19.0
12.2
80.0
2.5
2.0
29.3
32.4
40.0
208-230/60/3
187/253
47.0
30.1
225.0
9.2
3.0
78.6
86.1
110.0
240**
460/60/3
414/506
26.0
16.6
114.0
4.3
3.0
41.9
46.0
60.0
575/60/3
518/632
19.0
12.2
80.0
3.4
3.0
31.1
34.2
45.0
208-230/60/3
187/253
52.0
33.3
239.0
9.2
3.0
85.0
93.3
125.0
300
460/60/3
414/506
28.0
17.9
125.0
4.3
3.0
44.4
48.9
60.0
575/60/3
518/632
20.0
12.8
80.0
3.4
3.0
32.4
35.6
45.0
*Ratings per each compressor - unit supplied with two
9/10/07
**With optional motor
***Ratings per each blower motor - Vertical models 160-300 supplied with two.
HACR circuit breaker in USA only
All fuses Class RK-5
Compressor*