beautypg.com

Diagnostic leds – Spectrum Controls 140 EHC 204 00sc User Manual

Page 11

background image

Quantum Series 140 EHC 204 00sc 140 EHC 208 00sc

12

Hardware

Description

Door (removable)

Covers the terminal block and includes an identification label for terminals.

Door label

Permits easy terminal identification.

LED indicators

Display operating and fault status of module.
Details are provided in “

Diagnostic LEDs

”.

Side label (nameplate)

Provides module identification.

Self-locking tabs

Secure module in rack slot.

Terminal block

Used for field wiring the module.

Diagnostic LEDs

The module supports the LEDs listed in table 1-1 . These LEDs help you identify the source of problems that

can occur during power-up or during normal operation. Power-up and operation diagnostics are explained in

chapter 5, “Maintenance and Diagnostics.”

Table 1-1 Module LEDs

LED Name

Color

State

State Description

Ready (Module Status)

Green

On

Module powered up and functioning normally.

Off

Module is not powered up.

Active

Green

On

Bus communication is established between module and PLC.

Off

No bus communication.

Fault

Red

On

Module self-test error or fatal hardware error. LED blinks to
indicate type of self-test error.

Blinking

Type of self-test error. Count the number of blinks before a

pause to determine the error code. Possible codes are listed in
the table below.

Channel Status (8 LEDs)

Green

On

Channel is enabled and a valid input signal is present. The
LED indicates the state of the counter enable bit. It does not
indicate the state of an external hardware gate. See description
of the counter enable bit in chapter 3, “Module Configuration.”

Table 1-2 Channel LEDs

Code (Number of Blinks)

Error Type

On Solid

No Faults

1

Frequency Limit Out of Range.

2

Counter Limit Out of Range.

3

Counter Preset Out Of Range.

4

Channel Pair Gate Enable Configuration Mismatch.

5

Quadrature Pair Configuration Mismatch.

6

Both Stop on 0 and Stop on Limit selected (Mutually exclusive).

7

Both Roll Over to Preset and Roll Under to Preset (Mutually exclusive).

8

Unrecognized parameter type.

This manual is related to the following products: