Appendix a specifications – Spectrum Controls 1769sc-IT6I User Manual
Page 53
![background image](/manuals/742128/53/background.png)
User’s Manual Pub. 0300244-01 Rev. A
Appendix A
Specifications
Specification
Description
Module ID Codes
Vendor ID = 58 (Decimal)
Product Type = 10 (Decimal)
Product Code = 100 (Decimal)
Configuration
6 isolated channels of thermocouple/millivolt inputs
Input Modes
Temperature or voltage
Input Types
Thermocouple types J, K, T, E, R, S, B, N, and L, and +/-50 mV and +/-100 mV
Dimensions
118 mm (height) x 87 mm (depth) x 35 mm (width)height including mounting tabs is 138 mm4.65 in.
(height) x 3.43 in (depth) x 1.38 in (width)height including mounting tabs is 5.43 in.
Approximate Shipping Weight
(with carton)
276g (0.61 lbs.)
Storage Temperature
-40°C to +85°C (-40°F to +185°F)
Operating Temperature
0°C to +60°C (32°F to +140°F)
Operating Humidity
5% to 95% non-condensing
Operating Altitude
2000 meters (6561 feet)
Vibration 5g@
10–500Hz
Shock
Unpackaged (Non-operating)
½ Sine Shock Wave 20g@9ms, 3 shocks/axis
Unpackaged (Operating)
½ Sine shock Wave 30g@11ms, 1 shock/axis
Agency Certification
C-UL certified (under CSA C22.2 No. 142)
UL 508 listed
CE compliant for all applicable directives
Hazardous Environment Class
Class I, Division 2, Hazardous Location, Groups A, B, C, D
(ISA 12.12.01, C-UL under CSA C22.2 No. 213)
Operating Temperature Code T5
Radiated and
Conducted Emissions
IEC61000-6-4 FCC Part 15B Class A
Electrical /EMC:
The module has passed testing at the following levels:
ESD Immunity
(IEC61000-4-2)
4 kV contact, 8 kV air
Radiated Immunity
(IEC61000-4-3)
10 V/m, 80 to 1000 MHz, 80% amplitude modulation, 900 MHz & 1890 MHz 100% amplitude
modulation
Fast Transient Burst
(IEC61000-4-4)
4 kV
Surge Immunity
(IEC61000-4-5)
2 kV Line - Line, 4 kV Line - Gnd
Conducted Immunity
(IEC61000-4-6)
10V, 0.15 to 80 MHz
Fault detection
Open circuit detection, over-range and under-range error bits.
Open circuit detection time is equal to the channel update time.
CMRR
>100 dB at 50 Hz (4.17 Hz, 10 Hz, 16.7 Hz filter)
>100 dB at 60 Hz (4.17 Hz, 10 Hz, 19.6 Hz filter)
NMRR
>65 dB at 50 Hz (4.17 Hz, 10 Hz, 16.7 Hz filter)
>65 dB at 60 Hz (4.17 Hz, 10 Hz, 19.6Hz filter)
Input Impedance
> 1M ohms
Calibrated Accuracy
Linearization per ITS-90, DIN 43710
Thermocouple Type J
+/- 0.6 degrees C maximum @ 25°C for
4.17 Hz, 10 Hz, 16.7 Hz, and 19.6 Hz filters.
+/- 0.9 degrees C maximum @ 0 – 60°C for
4.17 Hz, 10 Hz, 16.7 Hz, and 19.6 Hz filters.