Circuit Board Replacement

Disconnect power to the unit.

Remove the housing cover.

Slide out PC board.

Disconnect power wiring and sensor plugs J1 and J2. (See

) Remove the ground

screw in the housing bottom.

Slide the ring terminal over the ground screw and replace it into the housing bottom.

Slide the new board into the control housing.

Connect the sensor plugs to the new board. One sensor wire plugs into J2. The other

sensor wire plugs into J1.



Reconnect power and replace the housing cover.

Replacement Circuit Boards
Match the characters of your model number with those shown below to select the proper
replacement board part number. Accessory designators are located at the end of the model
number in no particular order.

Accessory Designator

Model Number

with DT

without DT

701

4-U-P9-C

38-123

38-125

Cable Shielding

Probe Wire Shield Bead

Short/Fat Bead

Power Wire Shield Bead

Install end of bead as close

to cable gland as possible

2 loops

Positive

Negative

2 loops

Long/Slender

Bead

In order to achieve the stated accuracy of +/-1mA, a shielded cable, cable gland and shield-
ed beads must be used. SOR recommends using a shielded cable made of PVC insulation
around a tinned copper braid shield (Offlex CY cable or equivalent). Refer to illustrations
below for installation of shield beads