beautypg.com

SOR Single Point Ultrasonic Level Switch User Manual

Page 5

background image

Form 841 (08.13) ©SOR Inc.

5/16

Ensure that wiring conforms to all applicable local and national electrical codes and install
unit(s) according to relevant national and local safety codes.

Make sure the power source is turned off.

Power Supply Voltage (Volts)

Maximum Loop Resistance (Ohms)

(including Barrier Resistance

1500
1400
1300
1200
1100
1000

900
800
700
600
500
400
300
200
100

0

1 Ohm at

11 VDC

0 5 10

15

20

25

30

35

1470 Ohms

at 36 VDC

765 Ohms

at 24 VDC

Loop Resistance vs. Power Supply Voltage

1000

Ohms at

28 VDC

1118 Ohms

at 30 VDC

Remove the housing

cover.

Pull power and signal

wires through the

conduit connection and
into the control housing.

Locate TB1 on the

control board. (See

)

Terminals are labeled “+“
and “-“. Connect power
leads to the proper

terminals.

Do not exceed the

maximum

loop

resistance for the circuit.
(See

)