beautypg.com

Time delay switch settings – SOR Single Point Ultrasonic Level Switch User Manual

Page 7

background image

Form 841 (08.13) ©SOR Inc.

7/16

Time Delay Switch Settings

Off Delay Switches

J1 Receive

Jack

On Delay
Switches

Wet Probe
Switch

Yellow LED

Red LED

Loop Power Terminals

Remove the housing cover.

Locate off and on delay switches. (See

)

Set the on and off delay timers by moving the switches according to the chart below.

Off Delay Switch

set for 2 seconds

(switch #4 is on, all other switches are off)

On Delay Switch

set for 0 seconds

(all switches off)

ON 1 2

3

4

ON 1 2

3

4

Delay (seconds)

Position 1

Position 2

Position 3

Position 4

0

OFF

OFF

OFF

OFF

1

OFF

OFF

ON

ON

2

OFF

OFF

OFF

ON

5

OFF

OFF

ON

OFF

10

ON

ON

ON

ON

15

OFF

ON

OFF

OFF

20

ON

OFF

OFF

ON

30

ON

OFF

OFF

OFF

45

OFF

ON

OFF

ON

60

OFF

ON

ON

OFF

90

ON

ON

OFF

OFF

120

OFF

ON

ON

ON

180

ON

OFF

ON

OFF

240

ON

OFF

ON

ON

300

ON

ON

OFF

ON

600

ON

ON

ON

OFF

The delay timer is present in units which
contain a DT near the end of the model
number. Time delays are available as shown
in the Time Delay Switch Settings chart
below. Two sets of switches located inside
the electronics housing control the delay
timer. (See

)

On Delay = sensor dry

sensor wet

Off Delay = sensor wet