SOR 815PT Smart Pressure Transmitter User Manual
Page 12

12/24
Form 1571 (10.13) ©SOR Inc.
HART
Command
Description
Command Data
Command Reply Data
Byte
Description
Byte
Description
18
Write tag,
descriptor, date
0-5
Tag
0-5
Tag
6-17
Descriptor
6-17
Descriptor
18-20
Date
(dd-mm-yyyy)
18-20
Date (dd-mm-yyyy)
19
Write final
assembly
number
0-2
Final assembly
number
0-2
Final assembly number
20
Read long tag
Read only
0-31
Long tag
21
Read unique
identifier
associated with
long tag
0-31
Long tag
0
Always 254
1
Manufacturer ID
2
Device type code
3
Number of preambles
4
Universal command revision
5
Transmit-specific command
revision
6
Software revision
7
Hardware revision
8
Device function flags
9-11
Device ID number
12
Minimum number of preambles
13
Maximum number of preambles
14-15
Configuration change counter
16
Extended field device status
22
Write long tag
0-31
Long tag
0-31
Long tag
33
Read device
variables
0
Transmit variable
code slot 0
0
Transmit variable code slot 0
1
Transmit variable
code slot 1
1
Units code slot 0
2
Transmit variable
code slot 2
2-5
Variable slot 0
3
Transmit variable
code slot 3
6
Transmit variable code slot 1
7
Units code slot 1
8-11
Variable slot 1
12
Transmit variable code slot 2
13
Units code slot 2
14-17
Variable slot 2
18
Transmit variable code slot 3
19
Units code slot 3
20-23
Variable slot 3