beautypg.com

SOR 815PT Smart Pressure Transmitter User Manual

Page 10

background image

10/24

Form 1571 (10.13) ©SOR Inc.

HART

Command

Description

Command Data

Command Reply Data

Byte

Description

Byte

Description

9

(cont)

Read device

variables with

status

6

Device variable

code slot 6

9

Slot 1: Device variable class

7

Device variable

code slot 7

10

Slot 1: Units code

11-14

Slot 1: Device variable value

15

Slot 1: Device variable status

16

Slot 2: Device variable code

17

Slot 2: Device variable class

18

Slot 2: Units code

19-22

Slot 2: Device variable value

23

Slot 2: Device variable status

24

Slot 3: Device variable code

25

Slot 3: Device variable class

26

Slot 3: Units code

27-30

Slot 3: Device variable value

31

Slot 3: Device variable status

32

Slot 4: Device variable code

33

Slot 4: Device variable class

34

Slot 4: Units code

35-38

Slot 4: Device variable value

39

Slot 4: Device variable status

40

Slot 5: Device variable code

41

Slot 5: Device variable class

42

Slot 5: Units code

43-46

Slot 5: Device variable value

47

Slot 5: Device variable status

48

Slot 6: Device variable code

49

Slot 6: Device variable class

50

Slot 6: Units code

51-54

Slot 6: Device variable value

55

Slot 6: Device variable status

56

Slot 7: Device variable code

57

Slot 7: Device variable class

58

Slot 7: Units code

59-62

Slot 7: Device variable value

63

Slot 7: Device variable status

64-67

Timestamp