Saving the Configuration
Note:
Power must be maintained during save and undo commands. If power is interrupted, the
command may fail to complete. If this occurs, the unit will revert to factory defaults.
Save
Note:
If a save command is not executed, any changes will be lost when the
unit is put into standby power mode, or if power is interrupted.
Permanently save the current configuration. Note that, once saved, the configuration is
retained even if the unit is disconnected from power. The command format is:
MENU
→
SAVE
→
SAVE
,
OK
,
OK
Implicit: Configuration from previous save is retained to allow one-level of save-undo.
Save Undo
Revert to the configuration over-written by the last save. Repeating the save undo
command toggles between the last two saved configurations.
Hint:
To discard unsaved changes, temporarily enter standby mode.
The command format is:
MENU
→
SAVE
→
UNDO
,
OK
,
OK
Revert To Factory Settings
Sets all parameters to factory defaults, but does not save them into nonvolatile memory.
MENU
,
0
,
9
,
9
,
9
or
MENU
→
SAVE
→
FCTRY
,
OK
It is possible to reset only the current output resolution to default settings, while leaving
input setting unchanged. The command is:
MENU 0 9 9 8
Reset current output (only) to defaults for current
resolution