LINK Systems OmniLink - PLC Interface User Manual
Page 39

June 5, 2000
Man ual Rev 1 .0
5.12
Value:
Standard Numeric
Meaning:
Non-Zero if Clutch is engaged. This basically tells the PLC when the press is actually stroking.
Section 5.7.24
Parameter 024 - Crankshaft Direction of Rotation
Value:
Standard Numeric
Meaning:
0 for forward rotation. Non-Zero for reverse rotation.
Section 5.7.25
Parameter 025 - Stop Time Limit (Top)
Value:
Standard Numeric
Meaning:
The stopping time limit of the press in milliseconds for stops at the top of the stroke. See Press
Control Manual for more information.
Section 5.7.26
Parameter 026 - Stop Time Limit (Not at Top)
Value:
Standard Numeric
Meaning:
The stopping time limit of the press in milliseconds for stops NOT at the top of the stroke.
Section 5.7.27
Parameter 027 - Start Time Limit
Value:
Standard Numeric
Meaning:
The starting time limit of the press in milliseconds.
Section 5.7.28
Parameter 028 - Last Stop Time