LINK Systems OmniLink - PLC Interface User Manual
Page 36

June 5, 2000
Man ual Rev 1 .0
5.9
Meaning:
The numeric “current status” code for the “A” side of the Press Control. A zero for this value
indicates the press is ready to run. See parameter 082 for a command to get the actual text
description of this code.
Section 5.7.12
Parameter 012 - Press Control “B” Current Status Code
Value:
Standard Numeric
Meaning:
The numeric “current status” code for the “B” side of the Press Control. A zero for this value
indicates the press is ready to run. See parameter 083 for a command to get the actual text
description of this code.
Section 5.7.13
Parameter 013 - Press Control “A” Reason For Last Stop Code
Value:
Standard Numeric
Meaning:
The numeric “reason for last stop” code for the “A” side of the Press Control. See parameter 084 for
a command to get the actual text description of this code.
Section 5.7.14
Parameter 014 - Press Control “B” Reason For Last Stop Code
Value:
Standard Numeric
Meaning:
The numeric “reason for last stop” code for the “B” side of the Press Control. See parameter 085 for
a command to get the actual text description of this code.
Section 5.7.15
Parameter 015 - Auxiliary Message Selector Value
Value:
Standard Numeric
Meaning:
The value of the parallel auxiliary messages selector port. This is a seven bit port on the back of the
OmniLink OIT. This value can be 0 to 127.