LINK Systems OmniLink - PLC Interface User Manual
Page 38
June 5, 2000
Man ual Rev 1 .0
5.11
Section 5.7.19
Parameter 19 - Press Stroking Mode
Value:
Standard Numeric
Meaning:
Numeric code for the stroking mode of the press. The following codes apply:
1
=
Inch
2
=
Single Stroke
3
=
Auto Single Stroke
4
=
Continuous
5
=
Timed Inch
6
=
Setup/Stop Time Test
7
=
Continuous on Demand
8
=
Maintained Continuous
Section 5.7.20
Parameter 020 - Mode Select Key Flag
Value:
Standard Numeric
Meaning:
Non-Zero if Mode Select Key is active. The PLC can use this flag to give itself a mode select
capability without having to have a separate keyswitch.
Section 5.7.21
Parameter 021 - Motor Running Flag
Value:
Standard Numeric
Meaning:
Non-Zero if Motor is running.
Section 5.7.22
Parameter 022 - Clutch/Brake Flag