Electrical system, Service manual, Fuse check/replacement [razor sv 17 – Kent Razo E17 User Manual
Page 42

SERVICE MANUAL
ELECTRICAL SYSTEM
40
909 6577 000(1)2006-02
FUSE CHECK/REPLACEMENT [RAZOR SV 17]
1.
Check that the switches (5 and 6) are turned to “0”.
2.
Only for machine supplied without on-board battery charger: Disconnect the battery connector (36).
3.
Only for machine supplied with on-board battery charger: Remove the recovery water tank and disconnect the battery
negative terminal (50) according to the following procedure:
–
If there is recovery water in the tank (43), drain it through the hose (22).
–
Disconnect the vacuum hose (29) from the squeegee (17).
–
Open the cover (12).
–
Grasp the recovery water tank (A) in the area (B) and lift it, as shown in the figure, then disconnect the vacuum hose
(C) from the tank and remove the tank (A) together with the hoses (D) and (E).
4.
Remove the screws (F) and carefully pull out the electrical component box cover (G).
5.
Check/replace the fuses:
–
Brush fuse (H): 40 A
–
Vacuum system fuse (I): 30 A
–
Solenoid valve and electronic board fuse (J): 5 A
6.
Reassemble in the reverse order of disassembly.
S301369