beautypg.com

Solution system, Service manual, Troubleshooting [razor sv 17 - razor e 17 – Kent Razo E17 User Manual

Page 16

background image

SERVICE MANUAL

SOLUTION SYSTEM

14

909 6577 000(1)2006-02

TROUBLESHOOTING [RAZOR SV 17 - RAZOR E 17]

SMALL AMOUNT OF THE SOLUTION OR NO SOLUTION REACHES THE BRUSH

Possible causes:

1.

The solution filter is clogged/dirty (clean).

2.

The solution flow adjusting tap is clogged/dirty (replace).

3.

The solenoid valve is broken or there is an open in the electrical connection (replace the solenoid valve/repair the
electrical connection).

4.

There is debris in the solution tank clogging the output hole (clean the tank).

5.

There is debris in the solution hose clogging the solution flow (clean the hose).

THE SOLUTION REACHES THE BRUSH ALSO WHEN THE MACHINE IS OFF

Possible cause:

1.

The solenoid valve is broken (replace).

This manual is related to the following products: