Solution system, Service manual, Troubleshooting [razor sv 17 - razor e 17 – Kent Razo E17 User Manual
Page 16

SERVICE MANUAL
SOLUTION SYSTEM
14
909 6577 000(1)2006-02
TROUBLESHOOTING [RAZOR SV 17 - RAZOR E 17]
SMALL AMOUNT OF THE SOLUTION OR NO SOLUTION REACHES THE BRUSH
Possible causes:
1.
The solution filter is clogged/dirty (clean).
2.
The solution flow adjusting tap is clogged/dirty (replace).
3.
The solenoid valve is broken or there is an open in the electrical connection (replace the solenoid valve/repair the
electrical connection).
4.
There is debris in the solution tank clogging the output hole (clean the tank).
5.
There is debris in the solution hose clogging the solution flow (clean the hose).
THE SOLUTION REACHES THE BRUSH ALSO WHEN THE MACHINE IS OFF
Possible cause:
1.