Recovery water system, Service manual – Kent Razo E17 User Manual
Page 25
SERVICE MANUAL
RECOVERY WATER SYSTEM
909 6577 000(1)2006-02
23
RECOVERY WATER SYSTEM
TANK AND VACUUM GRID WITH FLOAT CLEANING [RAZOR SV 17 - RAZOR E 17]
1.
Drive the machine to the appointed disposal area.
2.
Check that the switches (5 and 6) are turned to “0”.
3.
If necessary, empty the tank (43) by means of the hose (22).
4.
Lift the cover (41), then wash with clean water the cover, the tank (43) and the vacuum grid (46).
Drain the water in the tank through the hose (22).
5.
If necessary, release the fasteners (A) and open the grid (B), recover the float (C), clean all the components and then
reinstall them.
6.
Check the recovery water tank cover gasket (D) for integrity.
If necessary replace the gasket (D) after removing it from its housing (E).
When assembling the new gasket, install its joint (F) in the central area, as shown in the figure.
7.
Check the gasket (G) bearing surface (D) for integrity and sealing capabilities.
8.
Check the compensation hole (H) for clogging.
9.
Close the cover (41).
S301372
NOTE
The gasket (D) creates vacuum in the tank that is necessary for vacuuming the recovery water.
NOTE
The hole (H) compensates the air in the cover interspaces, thus allowing the creation of vacuum in the
recovery water tank.