Premature weld termination, Weld termination due to end of weld/ground detect, Weld termination due to trigger lost – Dukane Ultrasonic Generator 403-575-00 User Manual

Page 95

background image

Premature Weld Termination

Weld Termination Due to End of Weld/Ground Detect

An End-of-Weld signal from the thruster limit switches and a Ground Detect signal

to the J602 connector cause the Weld portion of the cycle to terminate. A character-

istic of this type of weld termination is Hold Time. If the Hold portion of the cycle is

executed, then the weld was terminated by an end of weld/ground detect error. Figure

6-5 illustrates this condition.

PART

DOWNSTROKE

DOWNSTROKE

WELD TIME

WELD DIST

WELD ENERGY

HOLD

TOTAL

TOTAL

COUNT

TIME

DIST

PRESSURE 1

PRESSURE 1

PRESSURE 1

TIME

CYCLE TIME

STROKE

55

0.882

1.7928

0.015

0.0006

6.5

1.000

1.897

1.8094

Figure 6-5

Weld Termination Due to End of Weld/Ground Detect

Weld Termination Due to Trigger Lost

If the trigger type is set to Maintained, loss of the trigger signal causes an

immediate termination of the cycle when the ultrasound is applied. This

results in a shortened weld and zeroes for both Hold Time and Hold Distance.

Figure 6-6 shows a cycle terminated by a lost trigger input.

Figure 6-6

Weld Termination Due to Trigger Lost

PART

DOWNSTROKE

DOWNSTROKE

WELD TIME

WELD DIST

WELD ENERGY

HOLD

TOTAL

TOTAL

COUNT

TIME

DIST

PRESSURE 1

PRESSURE 1

PRESSURE 1

TIME

CYCLE TIME

STROKE

55

0.882

1.7928

0.015

0.0006

6.5

0

1.897

1.8094

Page 89

Dukane Manual Part No. 403-575-00

Section 6 - Troubleshooting