This section provides an overview of the generator rear
panel layout, which includes panel areas dedicated to var-
ious standard system functions and options that are avail-
able. Figure 3-6 illustrates a typical panel layout.
AC Power Inlet Panel
A
IEC Power Inlet Connector – Attaches to an IEC style
power cord.
B
Power Switch – Circuit Breaker – Used to switch
system power ON and OFF.
C
Chassis Grounding Stud – Chassis connection for a
protective earth ground.
The System I/O Panel
D
System Input Connector (J2) – Connections for sys-
tem control input signals.
E
System Output Connector (J3) – Connections for sys-
tem status output signals.
F
Ultrasound Output Connector (J1) – Coaxial high
voltage connection to ultrasonic stack.
G
Configuration Port Connector (J4) – Digital control
port to modify system parameters.
Figure 3-6
Generator Rear Panel - Pneumatic Press/Thruster
Options Module Panel
H
Communications board
Shown in the example above are these ports:
J9 - Ethernet, and
J10 - Serial RS232
K
Press interface board.
Shown in the example above are these ports:
J6 - Base/Abort
J5
-
Thruster
J11 - Encoder
REAR VIEW PNEUMATIC PRESS/THRUSTER
J4
J1
CONFIGURATION
ULTRASOUND
SYSTEM OUTPUTS
SYSTEM INPUTS
J2
J3
PE
LINE VOLTAGE:
200-240 Vac
50/60Hz, 15A
U.S. PATENT 5,880,580
OTHER PATENTS PENDING
POWER LINE OUTLET
MUST BE GROUNDED.
DISCONNECT LINE POWER
BEFORE REMOVING COVER.
ST. CHARLES IL 60174
MADE IN U.S.A.
DUKANE CORP
-WARNING-
I
0
J9 ETHERNET
J10 RS-232
J5 THRUSTER
J6 BASE/ABORT
J11 ENCODER
Rear Panel Layout Overview
NOTE
The press interface board is avail-
able in several different configura-
tions. See Section 8, Options for
more information.
A
C
B
D
E
F
G
K
H
Page 18
iQ Series
Ultrasonic Generator/Power Supply ES User’s Manual
Dukane Manual Part No. 403-575-00