Select Force as the type of trigger.
Then program the desired pounds of force.

Next, program Max Trigger Time. This provides a mea-

sure of safety insuring the welder will fault if for some

reason the welder never achieves the programmed trigger

force. See Figure 4-9.

NOTE

The example shown in Figure 4-9

assumes trigger force for a part with

four linear inches of weld would need

between 32 - 42 lbs of trigger force

A 20 inch linear weld may require

between 52 - 70 lbs. of trigger force.

See Figure 4-10, Initial Trigger Force

Settings.

Figure 4-9

iQ Explorer, Process Settings > Trigger > Type > Force > Max Trigger Time

Servo Step 5 - Process Settings > Trigger > Type

Figure 4-10

Suggested Initial Trigger Force Setting

Page 46

iQ Series

Ultrasonic Generator/Power Supply ES User’s Manual

Dukane Manual Part No. 403-575-00

Fo

rce (pounds)

Linear Weld Joint (inches)

110
105
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36

40

6.000

40