Pin

Signal Name

Cable Color Code

Signal Option Requirements

1

+22V

BLK

2

Spare Output

WHT

3

+22V Power Ground

RED

4

Programmable Status Output 1

GRN

5

Programmable Status Output 2

ORN

6

Ultrasound Active Status Output

BLU

7

Any Fault Status Output

WHT/BLK

8

Press Trigger Status Output

RED/BLK

9

System Overload Status Output

GRN/BLK

10

System Online Status Output

ORN/BLK

11

Press Top of Stroke Status Output

BLU/BLK

12

Current Loop OK Status Output

BLK/WHT

Not Used

13

Analog Monitor Signal Common

RED/WHT

14

Not Used

GRN/WHT

15

Power Signal Monitor Output

BLU/WHT

16

Amplitude Monitor Output

BLK/RED

17

Amplitude/Power Regulation Status Output

WHT/RED

18

MPC Ready Status Output

ORN/RED

Not Used

19

System Power OK Status Output

BLU/RED

20

Bad Part Status Output

RED/GRN

21

Good Part Status Output

ORN/GRN

22

System Ready Status Output

BLK/WHT/RED

23

Suspect Part Status Output

WHT/BLK/RED

24

Isolated Common

RED/BLK/WHT

25

Not Used

GRN/BLK/WHT

Table 3-III

System Output Connector Signals (J3)

Figure 3–11

DB-25F, Generator Output Connector (J3)

Figure 3–12

DB-25M, Generator Output Cable

Connector

1 3 5

7 9 11 13

15 17 19

21 23 25

13 11 9

7 5 3 1

25 23 21

19 17 15

System Outputs Connector

The

SYSTEM OUTPUTS

connector mounted on the gen-

erator I/O panel includes connections for all of the basic
system status and monitor output signals, which will typi-
cally connect to an automated control system. The cable
attached to this connector includes all of the available
system output signals, which will be read or monitored by
a digital input card or analog inputs on the user-supplied
automation controller.
The user can determine which signals are appropriate for
each welding application.

The system monitor output signals are analog signals used
to monitor ultrasonic amplitude setting and ultrasonic output
power levels, referenced to the Monitor Common (Pin 13).

Continued

Page 23

Dukane Manual Part No. 403-575-00

Section 3 - Installation