beautypg.com

Operational test of the acoustic stack – Dukane Ultrasonic Generator 403-575-00 User Manual

Page 80

background image

Operational Test of
the Acoustic Stack

The following test procedure is suggested before starting

the generator, to verify that the vibrational characteristics

of the stack fall within the range of the Digi-Trac. All

Dukane stack components are manufactured to tolerance

specifications within this range. A non-Dukane horn,

an improperly assembled stack, or a stack component

that is worn or damaged, can result in vibrational char-

acteristics outside these specifications, and will require

some adjustment. This test reveals the existence of any

problems and directs you to corrective action.
1. Check the following:

a. Make sure that the correct booster and horn for

the application are installed in the thruster.

b. Check the iQ Series system components for

proper grounding.

c. Check the ultrasound cable connections on the

generator and thruster for proper seating and

security.

d. Verify that the horn is not under load (not in

contact with a fixture or part).

e. Verify that the REAR panel AC switch is ON.

The front panel AC button should be RED.

2. Push the generator front panel power button to ON.

The power button will start to flash RED on and

off for LESS THAN 20 seconds. It will then turn

GREEN. This indicates that the system is operating.

If the power button display stops flashing but re-

mains RED, do not go any further, there is a problem

with the input circuit.

3. Using

iQ Explorer

, go to the Utilities tab. Press the

TEST button. See Figure 5-1.

a. System Power Output:

• If the power output display remains less

than 20% of the power supply's rated out-

put (See Table 10-III, Page 113.) and the

horn frequency (ie: 220 Press) is within

19,500 Hz and 20,500 Hz, the stack is

operational.

(340 Press) within: 29,500-30,500 Hz, &

39,500-40,500 Hz.

• If the power output exceeds the 20% indica-

tion, there may be a problem with the stack.

Figure 5-1

i

Q

Explorer Utilities TEST Button

TEST

Button

Continued

Page 74

iQ Series

Ultrasonic Generator/Power Supply ES User’s Manual

Dukane Manual Part No. 403-575-00