Pneumatic Step 5 - Process Settings>Trigger

Trigger Type

-

Select Force as the Trigger Type.

Program a force value.

For this example we used values typical for welding an

energy director part with approximately 10 inches of

linear weld joint. This type of weld may need about 50

pounds of trigger force.

See Figure 4-28

.

Figure 4-28

Suggested Initial Trigger Force

Max Trigger Time

-

Program a Max Trigger Time

of 3 seconds. This is the allowable cycle time from weld

initiation until the welder develops the programmed

force. Max Trigger Time will time the cycle out should

the machine, for some reason, not reach its programmed

force value.

Compensation Point

- For a basic setup this value

can be programmed at zero. Typically force values

above 10 pounds are programmed at zero.
See Figure 4-29 on the next page.

Continued