Ac power requirements – Dukane Ultrasonic Generator 403-575-00 User Manual
Page 119
AC Power Requirements
NOTES:
An X used above in the Model Numbers is a “wildcard” character meaning any valid character code combination.
Maximum line current requirement is specified at the minimum nominal AC line voltage and the rated power level.
Table 10- III
AC Power Requirements
Operating
Frequency
Generator
Model Number
Overload
Power
Ratings
(Watts)
Input AC Power Requirements
Nominal AC Volt
@ Maximum RMS Current
North America/
Japan
AC Outlet Rating
15kHz
15HS360-2A-XX-XX
3600
200-240V 50/60 Hz @ 25 Amps
30 Amps
15kHz
15HS480-2A-XX-XX
4800
200-240V 50/60 Hz @ 30 Amps
20kHz
20HS120-1A-XX-XX
1200
100-120V 50/60 Hz @ 15 Amps
15 Amps
20kHz
20HS120-2A-XX-XX
1200
200-240V 50/60 Hz @ 8 Amps
20kHz
20HS180-2A-XX-XX
1800
200-240V 50/60 Hz @ 12 Amps
20kHz
20HS240-2A-XX-XX
2400
200-240V 50/60 Hz @ 15 Amps
20kHz
20HS360-2A-XX-XX
3600
200-240V 50/60 Hz @ 25 Amps
30 Amps
20kHz
20HS480-2A-XX-XX
4800
200-240V 50/60 Hz @ 30 Amps
30kHz
30HS090-1A-XX-XX
900
100-120V 50/60 Hz @ 8 Amps
15 Amps
30kHz
30HS090-2A-XX-XX
900
200-240V 50/60 Hz @ 8 Amps
30kHz
30HS120-1A-XX-XX
1200
100-120V 50/60 Hz @ 15 Amps
30kHz
30HS120-2A-XX-XX
1200
200-240V 50/60 Hz @ 8 Amps
30kHz
30HS180-2A-XX-XX
1800
200-240V 50/60 Hz @ 12 Amps
40kHz
40HS060-1A-XX-XX
600
100-120V 50/60 Hz @ 8 Amps
40kHz
40HS060-2A-XX-XX
600
200-240V 50/60 Hz @ 5 Amps
40kHz
40HS090-1A-XX-XX
900
100-120V 50/60 Hz @ 15 Amps
40kHz
40HS090-2A-XX-XX
900
200-240V 50/60 Hz @ 8 Amps
40kHz
40HS120-1A-XX-XX
1200
100-120V 50/60 Hz @ 15 Amps
40kHz
40HS120-2A-XX-XX
1200
200-240V 50/60 Hz @ 8 Amps
Page 113
Dukane Manual Part No. 403-575-00
Section 10 - Specifications