beautypg.com

Connecting cables, Power cords – Dukane Ultrasonic Generator 403-575-00 User Manual

Page 35

background image

Connecting Cables

Step 1. Ground the generator chassis with the supplied

14-Gauge wire, and attach it to the grounding stud.

See Figure 3-7.

Step 2. Ultrasound (J1) - This output connects the Ul-

trasound Output of the iQ

Series generator to the

transducer, through a coaxial cable. The electrical

welding signal is transmitted through this cable.

Step 3. Operational Control (J201) - This cable runs from

J201 on the thruster to the generator's Thruster

connector (J5). The generator provides controls

for triggering the weld, operating the thruster’s

pneumatic system, and providing 24 VDC oper-

ating voltage through this cable. The press driver

card in the generator also provides monitoring for

these functions.

Step 4. Encoder (J11) (Optional) - The purpose of the

encoder cable is to connect the distance encoder

option to the generator's Encoder Port (J11).

Step 5. Ethernet Cable (J9) - Connects to the PC, LAN

port.

Step 6. RS-232 Cable (J10) - Connects to the PC, RS-232

port.

Step 7. Base/Abort Cable (J6) - Connects to the press

base plate connector (J35) or an automation PLC.

Step 8. Connect the AC power cord to the IEC power

inlet connector on the ultrasonic generator, and

plug the other end into an approved AC outlet.

Power Cords

The AC line cords supplied with the standard generators

are matched to the ultrasonic output power rating and the

continent of specified use. See Table 3-IV.

CAUTION

The power cord is equipped

with a three-prong, ground-

ed-type plug for your safety.

Whenever a two-slot recep-

tacle is encountered, we

strongly recommend that it is replaced

with a properly grounded three-lead

receptacle.

Have a qualified electrician do the

replacement in accordance with the

National Electrical Code and local

codes and ordinances. DO NOT cut

off the power cord grounding prong or

alter the plug in any way.

Continent of Use

Power Cord

Part Number

Power

North America

200 - 1110

240V, 15A

200 - 1541

240V, 10A

Continental Europe

200 - 1111

240V, 16A

200 - 1542

240 V, 10A

Table 3-IV

Power Cords

Page 29

Dukane Manual Part No. 403-575-00

Section 3 - Installation