Interpreting the model number – Dukane Ultrasonic Generator 403-575-00 User Manual
Page 120
Interpreting the Model Number
Inter
pr
eting the Model Number
20
HS
120 - 2
A
-
P6 -
C2
P
ow
er Le
vel
480 = 4800 W
atts
360 = 3600 W
atts
240 = 2400 W
atts
180 = 1800 W
atts
120 = 1200 W
atts
090 = 900 W
atts
060 = 600 W
atts
System Pr
ocess Contr
ols
A = Blank front panel
A
C Line Input
2 = 200-240 V for 5.25” tall chassis
1800 W and above
2 = 200-240 V for 3.5 tall chassis
1200 W and below
1 = 100-120 V for 5.25” tall chassis
1200 W and below (fixed power cord)
Nominal U/S F
requenc
y
15 = 15 kHz 20 = 20 kHz 30 = 30 kHz 40 = 40 kHz 50 = 50 kHz
Chassis Style
HS =
iQ
Series
Ultrasonic Press System ES
P4 = Dual Pressure Only P5 = Dual Pressure w/Distance P6 = EPR/Load Cell w/Distance P7 = Servo
Options Slot Boar
d
Communica
tions Boar
d
The example model number shown here is 20HS120-2A-P6-C2
This means: A 20kHz generator
, rated for 1,200 watts,
horizontal bench, 3.5” tall chassis, operating on a 200-240 V
AC line, designed for time
and energy weld control, with a distance, EPR and force press interface board and an RS-232 and Ethernet communications
board.
Figure 10-4
Interpreting the Model Number
Page 114
iQ Series
Ultrasonic Generator/Power Supply ES User’s Manual
Dukane Manual Part No. 403-575-00