beautypg.com

15 replacement of parts – Glow-worm Ultracom sxi User Manual

Page 59

background image

59

15.23 Access User Interface and Main PCB

For access, refer to section 15.1.
Remove control box retaining screw, see diagram 15.18.
Hinge down the control box.
Release the control box cover by carefully pressing the four

retaining clips, see diagram 15.18.

15.24 Main PCB

IMPORTANT: When replacing the board refer to instructions

supplied with the replacement.
For access, refer to section 15.23.
Remove the electrical connections to the PCB.
Ease back the four PCB retaining clips and withdraw the PCB

from the retaining lugs, see diagram 15.19.
When refitting the rear panel ensure the leads are not

trapped.

15.25 User Interface

IMPORTANT: When replacing the board refer to instructions

supplied with the replacement.
Refer to section 15.23 for access.
Remove main PCB, refer to section 15.24.
Remove electrical connection.
Gently ease back the retaining clips, see diagram 15.20.
Withdraw the board.

15.26 Fuse, Main PCB - Control Box

For access, refer to section 15.23.
The fuse is located at top left hand side of the PCB, see

diagram 15.19.

15.27 Control Box

For access, refer to section 15.23.
Remove relevant plugs and connectors, refer to wiring

diagram 14.4.
Withdraw grommets and leads so they are hanging loose.
Unthread the retaining cord and remove the control box. by

drawing it outwards away from its retaining slots, see diagram

15.18.

15.28 Inner Casing Panel Seal

For access, refer to section 15.1.
Refer to diagram 13.8.
Remove the inner casing panel.
To replace remove the old seal, thoroughly clean the casing

surfaces. Fit the new seal, it is supplied to the correct length.
Refit the inner casing panel.
NOTE: Ensure the seal is fitted correctly giving an airtight

joint.

13355

Diagram 15.18

13535

15 Replacement of Parts

RETAINING

CLIPS (4 OFF)

MAIN PCB

RETAINING

LUGS

FUSE

Diagram 15.19

Diagram 15.20

13536