beautypg.com

13 servicing, 2 spark electrode, 3 burner – Glow-worm Ultracom sxi User Manual

Page 43

background image

43

13 Servicing

ELECTRODE

GASKET

SPARK GAP

4mm

SECURING

SCREW

(2 OFF)

EARTH

LEAD

13273

Diagram 13.4

Diagram 13.5

13518

13.2 Spark Electrode

Disconnect the spark electrode plug and earth lead, see

diagram 13.5. Remove the two securing screws and withdraw

the spark electrode carefully from the combustion chamber,

see diagram 13.4.
Inspect the tips for damage.
Clean away any debris and check the spark gap is 3.5 to 4.5

mm.
Check the electrode gasket for signs of damage and replace

if necessary.

13266

Diagram 13.6

13.3 Burner

NOTE:
● The following procedure will require that you replace the

burner door seal and nyloc nuts.
● Removal of the burner is not necessary during a normal

service, but if it is removed it will require a new gasket, see

diagram 13.6.
● When replacing ensure that the sealing grommet, situated

below the gas valve is correctly re-seated.
Remove the gas pipe retaining clip.
Disconnect the gas valve electrical plug at the gas valve, see

diagram 13.5.
Disconnect the electrical plug from the fan.
Disconnect the spark electrode plug and earth lead, refer to

diagram 13.5.
Remove the five combustion chamber/burner door securing

nuts, see diagram 13.7, these should be discarded and

replaced with the new nylocs nuts supplied in the burner door

seal kit.
Gently remove the fan, gas valve and burner assembly from

the combustion chamber.
Clean the burner with a soft brush taking great care not to

damage the front insulation. DO NOT use wire or sharp

instruments to clean the holes of the burner.
Inspect the burner for any signs of damage.
Remove and discard the burner door seal and replace with

new, see diagram 13.7.