10.7 Standard Horizontal Flue - A2043400

Refer to diagram 10.11 for kit contents.

10.8 REAR Flue

With the flue elbow temporarily fitted, measure the distance

from the outside wall to the butt joint, see diagram

10.13

. If

the measurement ‘Y’ exceeds 665mm, then the appropriate

length of extension pipe is required. The minimum dimension

is 187mm to suit a 75mm min wall thickness. The flue can

project to a maximum of 600mm, if this is desirable, refer to

diagram 10.14.

10.9 SIDE Flue

With the flue elbow temporarily fitted, measure the distance

from the outside wall to the butt joint, see diagram 10.15

.

If

the measurement ‘Y’ exceeds 665mm, then the appropriate

length of extension pipe is required. The minimum dimension

for Lhd is 254 and Rhd 226 to suit a minimum wall thickness

of 75mm. The flue can project to a maximum of 600mm, if

this is desirable, refer to diagram 10.14.