13522

Diagram 15.8

15.14 Heating Flow Thermistor

For access, refer to section 15.1.
Refer to diagram 15.10.
Remove the electrical connections from the thermistor.
Remove the retaining clip from the flow pipe.
NOTE: When reconnecting, the polarity of the wiring to

thermistors is not important.

15.15 Heating Return Thermistor

For access, refer to section 15.1.
Refer to diagram 15.10.
Remove the electrical connections from the thermistor.
Remove the retaining clip from the return pipe.
NOTE: When reconnecting, the polarity of the wiring to

thermistors is not important.

15.16 Condense Trap and Siphonic Drain

For access, refer to section 15.1.
Refer to diagram 15.11.
Remove the igniter unit as described in section 15.3 to

improve accessibility.

Diagram 15.9

13281

15 Replacement of Parts

13316

Remove the securing clip from the heat exchanger adapter,

then disconnect the adapter and flexible hose.
Lift the siphon adapter and hose out of the condensate trap

and siphonic drain, do not disconnect the hose.
Disconnect the drain connection.
Slacken to disengage but do not remove the two securing

screws.
The condense trap will contain water, lift taking care not to

spill the water.
After replacement and before fitting the adapter fill the trap

with water.
Cleaning
Remove the condense trap as previously described.
Remove the float to clean it.
Remove any solids found.
Flush water through the trap to remove any remaining solids.
Check for any debris in the outlet hose of the condensate

drain and clean as necessary.