DaySequerra M4FM User Manual
Page 15
15
M4FM User Manual
Threshold: Low, Medium or High. (Default – low)
Delay: Use the arrow buttons to select from 1 – 300 seconds of delay (default – 15 sec)
Status: Use the arrows to toggle between Enabled or disabled to turn the alarm ‘ON’ and ‘OFF (default
– disabled)
Save: Saves all conditions and exits back to the Alarm menu.
Pilot Preset - Pilot Present alarm is factory set to alarm for a 19kHz pilot injection level
Delay: Use the arrow buttons to select from 1 – 300 seconds of delay (default – 15 sec)
Status: Use the arrows to toggle between Enabled or disabled to turn the alarm ‘ON’ and ‘OFF’ (default
– disabled)
Save: Saves all conditions and exits back to the Alarm menu.
Audio Loss - Silence Detect
Threshold: Navigate the arrow to Threshold and press ENTER to change the Threshold. A blinking
arrow will indicate the Threshold can be changed. Low, Medium and High are available to choose from.
Use the arrows to toggle through the choices. Press ENTER to make a selection and return to the
Audio Loss menu. “LOW” option sets audio loss threshold for approximately -60dB; “MED” option sets
audio loss threshold for approximately -40dB; and “HIGH” option sets audio loss threshold for
approximately -20dB.
Threshold: Low, Medium or High. (Default – low)
Delay: Use the arrow buttons to select from 1 – 300 seconds of delay (default 15 sec)
Status: Use the arrows to toggle between Enabled or disabled to turn the alarm ‘ON’ and ‘OFF’ (default
– disabled)
Save: Saves all conditions and exits back to the Alarm menu.
Over Modulation - The Carrier Over Modulation alarm is factory set to alarm for a level over 105% by
default. It can be manually set within the range of 100% - 125% in 1% increments.
Modulation Level: Use arrow buttons to select between 100% - 125% modulation in 1% increments
Delay: Use the arrow buttons to select from 1 – 300 seconds of delay (default – 15 sec)
Status: Use the arrows to toggle between Enabled or disabled to turn the alarm ‘ON’ and ‘OFF’ (default
– disabled)
Save: Saves all conditions and exits back to the Alarm menu.