12

The setting of output boundaries is accomplished by adjusting the potentiometers offset and gain (refer
to FIGURE 2).

Each adjustment affects the output in a different way. The offset adjustment is used to set the minimum
analog output point. When adjusted, it shifts the entire output response range. FIGURE 13 illustrates the
effect of adjusting the offset potentiometer. Notice how the offset changes but the “gain” remains the
same.

When the “gain” potentiometer is rotated clockwise, the gain is decreased and when rotated counter-
clockwise, the gain is increased. FIGURE 14 shows how potentiometer adjustment affects the gain, but
doesn't change the minimum output offset.

FIGURE 12

SET POINT ADJUSTMENT

FIGURE 13

OFFSET ADJUSTMENT

FIGURE 14

MAXIMUM OUTPUT (GAIN) ADJUSTMENT