34

Gap/Black Mark

Sensor Calibration

1.Turn off the power switch.

2. Hold on the button then turn on the power switch.

3 Release the button when LED becomes

red

and blinking. (Any

red will do during the 5 blinks).

It will calibrate the gap/black mark sensor sensitivity.
The LED color will be changed as following order

Amber

red

(5 blinks)

amber (5 blinks)

green

(5 blinks)

green/amber (5 blinks)

red/amber (5

blinks)

solid green

It calibrates the sensor and measures the label length.

Note:

Please select gap or black mark sensor by GAP or BLINE

command prior to calibrate the sensor.

For more information about GAP and BLINE command,

please refer to programming manual.

Gap/Black Mark

Sensor Calibratio,

Label Length

Measurement,

Self Test and enter

Dump Mode

1.Turn off the power switch.

2. Hold on the button then turn on the power switch.

3. Release the button when LED becomes

amber

and blinking.

(Any amber will do during the 5 blinks).

The LED color will be changed as following order.

Amber

red (5 blinks)

amber

(5 blinks)

green

(5 blinks)

green/amber (5 blinks)

red/amber (5

blinks)

solid green

It calibrates the sensor and measures the label length

and prints internal settings then enter the dump mode.

Note:

Please select gap or black mark sensor by GAP or BLINE

command prior to calibrate the sensor.

For more information about GAP and BLINE command,

please refer to programming manual.