4. Power on Utilities

There are six power-on utilities to set up and test printer hardware. These utilities are

activated by pressing FEED button and by turning on the printer power simultaneously.

The utilities are listed as below:

1. Gap/Black Mark sensor calibration

2. Gap/black mark sensor calibration, Self-test and Dump mode

3. Printer

initialization

4. Black mark sensor calibration

5. Gap sensor calibration

6. Skip

AUTO.BAS

4.1 Gap/Black Mark Sensor Calibration

Gap/black mark sensor sensitivity should be calibrated at the following conditions:

1. A brand new printer

2. Change label stock.

3. Printer initialization.

Please follow the steps below to calibrate the gap/black sensor:

1.Turn off the power switch.

2. Hold on the button then turn on the power switch.

3 Release the button when LED becomes

red

and blinking. (Any red will do during the 5

blinks).

It will calibrate the gap/black mark sensor sensitivity.
The LED color will be changed as following order

Amber

red

(5 blinks)

amber (5 blinks)

green (5 blinks)

green/amber (5

blinks)

red/amber (5 blinks)

solid green

It calibrates the sensor and measures the label length.

Note:

Please select gap or black mark sensor by GAP or BLINE command prior to

calibrate the sensor.

For more information about GAP and BLINE command, please refer to

programming manual.