AVENT TECHNICAL DATA

ESTIMATED FUEL FEED RATE CHART



WOOD PELLETS: Fuel consumption will vary depending on fuel size


Low fuel setting

16 ounces per hour

2.5 ounces in a 10 minute test

Medium fuel setting

24 ounces per hour

4 ounces in a 10 minute test

High

38 ounces per hour

6.4 ounces in a 10 minute test


These fuel consumption feed rates are an approximation. Each unit will vary with the type and size of
the fuel that is being burnt. The most important feed rates to check would be the # 1 setting and the
High setting to make sure that the low and high feeds are proper for the unit. If the feed rates are
drastically different contact your local dealer for circuit board factory adjustments. Do not get alarmed
if the feed rates are not the same as shown. As long as the low fire will stay lit and the high fire does
not overheat the unit and shut it down the unit is performing as it should.
The unit is designed to adapt to different size fuels and consumption circumstances.

If you are experiencing different feed rates than shown you will need to set the fuel feed rate on a lower
or higher setting to adjust for the differences in the fuel feed rate. The size and flow characteristics of
wood pellets vary from year to year and that alone will change the heat output of the unit. There is a
fine tune adjustment that the Reseller can make to the circuit board if the low fire will not stay lit or is
burning too hot. You will need to contact your local Reseller for this adjustment.

It is recommended that when the unit is first installed in the customer’s home that the unit be fired and
run for over an hour to see if the air adjustment is right for the fuel. Making the proper air adjustment
and making sure that proper outside air has been provided will allow the unit to perform properly.

The Avent is certified to burn premium quality wood pellets. Check with your local Reseller before
burning fuels not approved.
NOTE: The factory will not pay warranty service calls on problems that have come up on the
unit when the proper fuel, combustion air requirements and air adjustments have not been
checked.