PROBLEM

CAUSES

SOLUTIONS


? Fire burns with a lazy, orange flame
and/or fuel builds up in the grate and the
window gets sooted up.

♦ Insufficient combustion air.

♦ Feed rate too high.

♦ Wood pellets have too much

moisture / poor quality fuel / fuel
left over from previous season

♦ Combustion/Room Fan blower

plugged or going out.

♦ Venting/ Top of unit plugged with

fly ash.

♦ House does not have adequate

make up air (negative pressure)

♦ Firebox door not closed or does not

seal properly

♦ Top plate not secured properly


9 Check that damper control knob is

adjusted properly. Pull out to
increase fire burn.


9 Have your service technician check

the fine tune adjustments on the
circuit board.


9 Change to a better grade of fuel if

necessary.


9 Remove any clinkers or ash from

the firepot .


9 Clean out primary air holes in

firepot if plugged.




9 Check gasket seal around the door.

If the door is loose, adjust the
handle latch. A small adjustment
can be made to the door seal by
adjusting the door latch rod and /or
the door hinges. Replace the door
gasket if necessary.


9 Check for blockage in the air inlet

tube or exhaust pipe. Clean out as
necessary.



9 Replace combustion / room air

blower if necessary.


NOTE: Negative pressure in a home is
a serious issue. All Avent Wood Pellet
appliances should be installed with
outside air hookups
Also make sure that adequate ventilation
is supplied for the rest of the home or
the unit will become the air intake
causing problems.









TROUBLE SHOOTING GUIDE

Unplug stove before performing any maintenance work. Do not work on unit when it is hot.