IMPORTANT: ELECTRICAL WORK MUST BE PERFORMED BY AN AUTHORIZED
TECHNICIAN.
WARNING: THIS SECTION IS ONLY FOR QUALIFIED TECHNICIANS.
Avent Wood Pellet Wiring Diagram (DCX-5 Circuit Board)
Circuit Board fine tune feed adjustment
Warning: Never adjust any stove unless it has been thoroughly cleaned, flue checked and a
qualified technician has diagnosed the need for an adjustment.
• To adjust the low burn rate, slide the heat selector switch to the “1” or low setting and observe the
auger light. This will indicate when the auger is running.
• Turn the adjustable resister “L” clockwise to increase the burn rate, and counter-clockwise to
decrease the burn rate.
• To adjust the high burn rate, slide the heat selector switch to the “3” or high setting and turn the
adjustable resistor “H” clockwise to increase the burn rate, and counter-clockwise to decrease the
burn rate.
Note: Fan voltages are fixed and ay not be adjusted. The Medium fuel feed rate is fixed.
Recommended timings:
Low – 2.0 seconds on approximately
8.0 seconds off approximately
High- 2.0 seconds on approximately
3.0 seconds off approximately
Adjusting the feed rate is done by changing the off time between cycles
+
_
5 10
4 9
3 8
2 7
1 6
Auger
High Limit 225 deg. Snap disk
(normally closed)
Red
Red
Red
12 volt DC fan &
combustion air motor
Black
Pressure
switch
Common
Normally
Open
Normally
closed
Not
used
White
Blue
Blue
+
Yellow
12 volt DC
auger motor
DCX-5
circuit
board
Red
Low Temp. safety
sensor (normally open)
Red
Black
Battery
Terminals
Black
Red
Red
Green
Green
Transformer
120
vac
White
Black
Green
ground
Power
Cord
no nc (do not use)
yellow
Door auger
safety shut
off switch