IMPORTANT: ELECTRICAL WORK MUST BE PERFORMED BY AN AUTHORIZED
TECHNICIAN.

WARNING: THIS SECTION IS ONLY FOR QUALIFIED TECHNICIANS.

Avent Wood Pellet Wiring Diagram (DCX-5 Circuit Board)

Circuit Board fine tune feed adjustment

Warning: Never adjust any stove unless it has been thoroughly cleaned, flue checked and a
qualified technician has diagnosed the need for an adjustment.

• To adjust the low burn rate, slide the heat selector switch to the “1” or low setting and observe the

auger light. This will indicate when the auger is running.

• Turn the adjustable resister “L” clockwise to increase the burn rate, and counter-clockwise to

decrease the burn rate.

• To adjust the high burn rate, slide the heat selector switch to the “3” or high setting and turn the

adjustable resistor “H” clockwise to increase the burn rate, and counter-clockwise to decrease the
burn rate.


Note: Fan voltages are fixed and ay not be adjusted. The Medium fuel feed rate is fixed.
Recommended timings:

Low – 2.0 seconds on approximately

8.0 seconds off approximately

High- 2.0 seconds on approximately

3.0 seconds off approximately

Adjusting the feed rate is done by changing the off time between cycles

+

_

5 10
4 9
3 8
2 7
1 6

Auger

High Limit 225 deg. Snap disk
(normally closed)

Red

Red

Red

12 volt DC fan &
combustion air motor

Black

Pressure
switch

Common
Normally
Open
Normally
closed

Not
used

White

Blue

Blue

+

Yellow

12 volt DC
auger motor

DCX-5
circuit
board

Red

Low Temp. safety
sensor (normally open)

Red

Black

Battery
Terminals

Black

Red

Red

Green
Green

Transformer

120
vac

White
Black

Green
ground

Power
Cord

no nc (do not use)

yellow

Door auger
safety shut
off switch