American Energy Systems MagnuM Winchester User Manual
Page 46

46
PROBLEM
CAUSES
SOLUTIONS
? Fire goes out or stove shuts down
automatically.
♦
Hopper is empty.
♦
Fuel is not feeding.
♦
High limit temperature switch has
tripped.
♦
Vacuum pressure switch has
tripped.
♦
Poor quality or wet fuel.
♦
Combustion air too high.
♦
Fuel feed rate is too low.
9 Refill hopper.
9 See “Fuel will not feed” below.
9 Allow stove to cool for 1 hour and
relight after re-setting the high
temperature thermodisk. If this
problem persists, particularly at
lower burn rates, then the high limit
snap switch may need to be
replaced contact your authorized
MagnuM reseller.
9 Correct cause of vacuum pressure
switch tripping. Have an
authorized tech service unit. Install
outside air.
9 Replace fuel with proper fuel.
9 Adjust the damper to reduce
combustion airflow.
9 Have your MagnuM reseller adjust
the fuel control.
? Fuel will not feed.
♦
Hopper is empty.
♦
Auger, circuit board, high limit
switch tripped.
♦
Foreign object caught in auger.
♦
Fuel is dirty or wet.
♦
Auger, circuit board, pressure
switch or relay.
9 Check contents of the hopper. Add
fuel if necessary.
9 Check all operations, fuses, re-set
manual high limit thermodisk.
9 Clean out auger system.
9 Have your MagnuM reseller
diagnose the problem and replace
parts if needed.
? Stove runs for 10 minutes and then
shuts down.
♦
Exhaust gas is not up to
temperature. Started on too low of
heat level setting. Must be on # 3
heat level setting.
♦
Low limit snap switch not operating
correctly; may be defective.
♦
Wires to either the low limit snap
switch (mounted on the side of the
firebox) are loose or disconnected.
9 Relight the stove. Start on # 3 heat
level setting.
9 Have your MagnuM reseller replace
the low limit switch.
9 Contact your MagnuM reseller for
service.
? Blower will not shut off after the fuel
has been switched off and the stove has
cooled down.
♦
Low limit snap switch has failed in
the closed position.
♦
Unit has not cooled down yet.
9 Have your MagnuM reseller replace
the low limit snap switch.
9 It can take up to 1 hour for the unit
to cool down enough for the blower
to shut off. If it takes longer than 2
hours for the blower to shut off or if
it fails to shut off contact your local
MagnuM service technician.