beautypg.com

Trouble shooting guide – American Energy Systems MagnuM Winchester User Manual

Page 45

background image

45

TROUBLE SHOOTING GUIDE

Unplug power to the appliance before performing any service.

PROBLEM

CAUSES

SOLUTIONS


? Fire burns with a lazy, orange flame

Insufficient combustion air.

nual draft

re, has too

h content

er

ash or ice.

uate make

9 Remove any clinkers or ash from

the firepot by using scraping tool.
Clean entire system.

9 Clean out primary air in firepot

holes if plugged.

9 Empty ash drawer. Clean out heat

exchangers by removing the access
plates.

9 Change to a better grade of fuel if

necessary.


9 Check that damper control knob is

adjusted properly. Pull out to
increase fire burn.


9 Push ash cleanout slides in.

9 Check gasket seal around the door.

If the door is loose, adjust the
handle latch. A small adjustment
can be made to the door seal by
adjusting the door latch rod and/or
the door hinges. Replace the door
gasket if necessary.

9 Check for blockage in the air inlet

tube or exhaust pipe. Clean out as
needed.

9 Check combustion/exhaust blower

impeller. This can be done by
removing the exhaust pipe and
shining a light into the tube or using
the access plug on the exhaust
manifold side plate.

9 Replace combustion/exhaust blower

if needed.

NOTE: Negative pressure in a home is
a serious issue. All MagnuM appliances
should be installed with outside air
hookups.

Also, make sure that adequate
ventilation is supplied for the rest of the
home, or the unit will become the air
intake causing problems.

and/or fuel builds up in the firepot and
the glass will soot up quickly.

Feed rate too high for ma

setting.

Fuel has too much moistu

many fines, too high of as
or is old.

Combustion/Exhaust blow

plugged or going out.

Venting plugged with fly

Home does not have adeq

up air (negative pressure).

Ash slides are pulled out.