Power Specifications

Table 2-5

provides the power requirements for the 300 MHz and 800 MHz versions of the CoreModule 430.

Operating configurations:

In-rush operating configuration includes CRT video, 256MB DDR RAM, and power.

Idle operating configuration includes the in-rush configuration as well as on-board Compact Flash with
64MB card, and one keyboard.

BIT = Burn-In-Test. Operating configuration includes idle configuration as well as two serial port loop-
backs, one Ethernet connection, and four USB Compact Flash readers with 64MB Compact Flash.

Environmental Specifications

Table 2-6

provides the operating and storage condition ranges required for this module.

Thermal/Cooling Requirements

The CPU is the primary source of heat on the board. The 800 MHz version of the CoreModule 430 CPU is

designed to operate at its maximum speed and requires a heatsink (provided). The 300 MHz version of the

CoreModule 430 CPU does not require a heatsink.

NOTE

All dimensions are given in inches. Pin 1 is shown as a black pin (square or
round) on vertical headers or connectors in all illustrations. Black dots on right-
angle headers or connectors indicate pin 2.

The Compact Flash socket (J12) exceeds the PC/104 height limitation by 0.2

inches.

Table 2-5. Power Supply Requirements

Parameter

Characteristics for 300 MHz CPU Characteristics for 800 MHz CPU

Input Type

Regulated DC voltages

Regulated DC voltages

Peak In-rush Current

14.80A (74.00W)

14.86A (74.30W)

Idle Current

1.30A (6.51W)

1.42A (7.12W)

BIT Current (Typical)

1.32A (6.58W)

1.44A (7.19W)

Table 2-6. Environmental Requirements

Parameter

Conditions

Temperature
Operating

–20° to +70° C (–4° to +158° F)

Extended (Optional)

–40° to +85° C (–40° to +185° F)

Storage

–55° to +85° C (–67° to +185° F)

Humidity
Operating

5% to 90% relative humidity, non-condensing

Non-operating

5% to 95% relative humidity, non-condensing