ADLINK PCI-8144 User Manual
Page 71
MotionCreatorPro
61
In “Cont. Move,” both the value and sing is effective. –
5000.0 means 5000.0 in the minus direction.
Z
Accel. Time: Set the acceleration time in units of sec-
ond. Tdec is the same as tacc.
Z
Move Delay: This setting is effective only when repeat
mode is set “On.” It will cause the 8144 to delay for a
specified time before it continues to the next motion.
14.Play Key:
X
Left play button: Clicking this button will cause the 8144
start to outlet pulses according to previous setting.
Z
In “Relative Mode,” it causes the axis to move forward.
Z
In “Cont. Move,” it causes the axis to start to move
according to the velocity setting.
X
Right play button: Clicking this button will cause the 8144
start to outlet pulses according to previous setting.
Z
In “Relative Mode,” it causes the axis to move back-
wards.
Z
In “Cont. Move,” it causes the axis to start to move
according to the velocity setting, but in the opposite
direction.
15.Stop Button: Clicking this button will cause the 8144 to
stop. The related function is _8144_emg_stop().
16.I/O Status: The status of motion I/O. Light-On means
Active, while Light-Off indicates inactive. The related
function is _8144_get_mio_status().
17.Motion Status: The status of motion when running.
Light-On means Active, while Light-Off indicates inac-
tive. The related function is
_8144_motion_status()
.