Operation Theory
41
Then
X
Acquisition sequence of channels: 1, 2, 0, 2, 1, 2, 0, 2, 1, 2,
0, 2
X
Sampling interval: 160/40 Ms = 4 µs
X
Scan interval: 640/40 Ms = 16 µs
X
Equivalent sampling rate of ch0, ch1: 62.5 kHz
X
Equivalent sampling rate of ch2: 125 kHz