beautypg.com

Ssi connector – ADLINK PXI-2208 User Manual

Page 40

background image

28

Signal Connections

SSI Connector

*Pin 5 and 13 are reserved for DAQ/PXI-2208.

SSI Connector Signal Description:

SSI_TIMEBASE

1

2

DGND

SSI_ADCONV

3

4

DGND

SSI_DAWR / RESERVED*

5

6

DGND

SSI_SCAN_START

7

8

DGND

RESERVED

9

10

DGND

SSI_AD_TRIG

11

12

DGND

SSI_DA_TRIG / RESERVED*

13

14

DGND

RESERVED

15

16

DGND

RESERVED

17

18

DGND

RESERVED

19

20

DGND

Table 3-6: SSI Connector Pin Assignment

SSI Timing Signal Setting

Function

SSI_TIMEBASE

Master Send the TIMEBASE out

Slave

Accept the SSI_TIMEBASE to replace the internal
TIMEBASE signal.

SSI_ADCONV

Master Send the ADCONV out

Slave

Accept the SSI_ADCONV to replace the internal
ADCONV signal.

SSI_SCAN_START

Master Send the SCAN_START out

Slave

Accept the SSI_SCAN_START to replace the internal
SCAN_START signal.

SSI_AD_TRIG

Master Send the internal AD_TRIG out

Slave

Accept the SSI_AD_TRIG as the digital trigger signal.

SSI_DAWR

Master Send the DAWR out.

Slave

Accept the SSI_DAWR to replace the internal DAWR
signal.

SSI_DA_TRIG

Master Send the DA_TRIG out.

Slave

Accept the SSI_DA_TRIG as the digital trigger signal.

Table 3-7: SSI Connector Legend

This manual is related to the following products: