500 Series Display Cases Service and Installation Manual

For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com

4

Location

To meet NSF standards, all units must be sealed

to the floor.

Be sure the location chosen has a floor strong enough

to support the total weight of the cabinet and contents.

Contents fully loaded in this product line can weigh as much

as 1500 lbs. Reinforce the floor as necessary to provide for

maximum loading.
For the most efficient refrigeration, be sure to provide good

air circulation inside and out. Do not pack the refrigerator so

full that air cannot circulate. Be sure that the exterior of the

unit has access to ample air. Avoid hot corners and locations

near stoves and ovens.

Leveling

To level unit, simply lower the four adjustable rubber feet

located under the unit to the floor and adjust until unit is

level. A level cabinet will perform better because the drain

will empty properly, the doors will line up with the frames

correctly and the cabinet will not be subject to undue strain.

Plumbing

Self-contained models are standard with a condensate

evaporator. If the evaporator fails, the unit’s drain must have

an outlet to an appropriate drainage area or container.

Moisture collecting from improper drainage

can create a slippery surface on the floor and

a hazard to employees. It is the owner’s and

operator’s responsibility to provide a container or

outlet for drainage.

Electrical connection

Refer to the amperage data on page 3, the serial tag, your

local code or the National Electrical Code to be sure the

unit is connected to the proper power source. A protected

circuit of the correct voltage and amperage must be run for

connection of the line cord, or permanent connection to the

unit.
Self-contained units have an ON/OFF switch located on

the operators side. Simply turn the switch to ON to begin

operation.

The power switch should be turned to OFF and the

unit disconnected from the power source whenever

performing service or maintenance functions.

CAUTION

On self-contained models, after turning the ON/OFF switch

to ON, the unit’s compressor will begin operating. Delfield

display cases are designed to maintain an operational

temperature of 36°F to 40°F.
Do not load the storage area in a way that restricts the air

flow. Overloading will result in the loss of temperature. Do

not throw items into the storage area. The interior of the

cabinet and the blower coil may be damaged by this type of

neglect, which is not covered under your warranty.

These units use HFC-404A refrigerant, and

have a lock-out high pressure limiting device.

Under severe overloading conditions, in the

event of a condenser fan failure or a plugged or

blocked condenser, this device may shut down

the refrigeration system. See page 17 for part number

information if a replacement is required.

INSTALLATION: 500 CD, CR, CRR & OR

OPERATION: 500 CD, CR, CRR & OR